Hks turbo timer 4 manual






















Maximum timer duration is 30 minutes. Accurate time duration can be selected by manual setting. Handbrake detective safety circuit; High capacity relay; Timer operation stops under unstable conditions caused by low voltage of a battery, etc. Application: Turbo . Ignition: 25A / Accessary: 25A. Stand-by Current: 10mA or lower. Operating Temperature: 20~60℃ (-4 to °F) Setting Time Range: :1, 3, 5, 10, and 30 min. Example of One Minute Time Range: Frequent after-idling for daily use. Idling takes place after street driving, commuting, etc. HKS Turbo Timer IV Installation for – Supra Twin Turbo 15 Preset times – 0 – 3 mins; 30 sec intervals A wiring diagram schematic is depicted below for those who would like to 9 female “bullet” connectors (crimp type); 9 male “bullet” connectors (crimp type); 1 wire tap connector; Double faced tape; Velcro.


Turbo Timer Harness. Key Switch. Parking Brake Switch (2) Reference the below diagram: Remove the key switch connecter as shown in the Manual Mode: can be set in increments of 10 seconds from 0 - 10 min. 2 Selectable. The HKS Turbo Timer type-1 is a turbo timer that. Turbo Timer for the vehicles equipped with push-start ignition. The HKS Turbo Timer Type-1 also features various measurement functions including 1/4 mile timer, timer and a stopwatch function that can be used for lap timing. The Turbo-Timer Type-1 can read in either MPH/SAE or KPH/Metric. Slim and separate design of simple function turbo timer. HKS USA N Roosevelt Ave. Chandler, AZ support@www.doorway.ru


Installing an HKS Turbo Timer Installing an HKS Turbo Timer (IV) ~~~~~ Vehicle: Toyota MR2 Turbo (Canadian Model) Author: Geoff Seeley Version: Date: Octo Changes since ~~~~~ - added basic wiring diagram Changes since ~~~~~ - added section on timer operation - added to testing section Changes since ~~~~~ - found out the the version of the turbo timer I have is. Functions validated by a long-seller sold over ,・・・ Development Story How to Use Specifications of TT10 Application (Harness) This product is a device applicable to a vehicle starts the engine using the ignition key. 10th generation Turbo Timer evolutionally advanced with the turbo engines. Begin as a must for the turbo engine. The original turbo timer was developed to prevent. Maximum timer duration is 30 minutes. Accurate time duration can be selected by manual setting. Handbrake detective safety circuit; High capacity relay; Timer operation stops under unstable conditions caused by low voltage of a battery, etc. Application: Turbo vehicles that start the engine using the ignition key.

0コメント

  • 1000 / 1000